| Accessible entry points to a soft contained structure |
With 3 or fewer entry points, at least 1 must be on an accessible route. With 4 or more, at least 2 must be. |
2010 ADA Standards, section 206.2.17.2 |
| Vertical clearance where an accessible route serves ground-level play components |
80 in (2,030 mm) minimum |
2010 ADA Standards, section 1008.2 |
| Clear width of the accessible route at ground level |
60 in (1,525 mm) minimum. 44 in (1,120 mm) is permitted in play areas under 1,000 ft² only if at least one turning space is provided where the restricted route exceeds 30 ft. 36 in (915 mm) is permitted for runs of 60 in maximum, and reduced segments must be separated by segments at least 60 in wide and 60 in long |
2010 ADA Standards, section 1008.2.4.1, exceptions 1 and 2 |
| How the accessible route reaches an elevated soft-contained deck |
A transfer system may form part of the accessible route for a soft contained play structure — you are not obliged to ramp it. Decide this at drawing stage; retrofitting a transfer point into a finished structure is expensive |
2010 ADA Standards, section 1008.2.2 exception, referring to 1008.3 |
| Age band the main structure is sized for |
2 to 12 years is the band the governing product standard is written against — specifically the 5th percentile 2-year-old to the 95th percentile 12-year-old |
ASTM F1918-21, scope 1.2 |
| Separate provision for under-2s |
A toddler area for 6 to 23 months falls outside both the soft-contained and the public-playground standards and is covered by its own document |
ASTM F2373; CPSC Public Playground Safety Handbook |
| Ground-level deck height and adult access |
Set so that an adult can enter and reach a child. One US operator's build, written up by an industry consultant, used 4 ft grids including the entry level in a venue with 24 ft ceilings; the reported result was that staff could not comfortably get in during an emergency, older children stopped using it, and revenue reached 65% of expectation. A single account, not a survey — treat it as a question to ask, not a number to copy |
ASTM F1918 carries a named Evacuation section; the 4 ft outcome is one operator's reported experience |
| Age separation between zones |
Keep older children out of toddler areas; smaller children are disadvantaged in collisions |
CPSC soft contained play equipment guidance |
| Slide and climber termination into a ball pool |
Specify the exit geometry explicitly; this interface is where collision risk concentrates |
CPSC review of soft contained play centres |
| Trampoline zone, if included |
Governed as a court over its whole life — design, manufacture, installation, operation, maintenance, inspection and major modification |
ASTM F2970-25, scope 1.1–1.2 |
| Inflatable attractions, if included |
A separate device class with its own standard, not part of the play structure package. Its scope names family entertainment centers too, and covers bouncing, climbing, sliding, obstacle-course running and interactive play |
ASTM F2374-24 |